Skip to product information
1 of 1

Eaton 5PX1000RTNG2 1000VA/1000W Rack/Tower Line-Interactive UPS with Network Card

Delivery Time: 0-3 days
Brand EATON
Model Number 5PX1000RTNG2
EpicRise Warranty First Year
Product Highlights

• Unity power factor delivers 1000W at 1000VA rating, 11% more usable power than traditional UPS designs for modern high-efficiency servers

• Pre-installed gigabit network card (NETWORK-M2) with UL 2900-1 and IEC 62443-4-2 cybersecurity compliance for secure remote management

• 98% efficiency at maximum load with Energy Star 2.0 certification reduces operating costs and heat generation in rack environments

• Advanced battery management (ABM) extends battery service life by 50% with hot-swappable design for zero-downtime maintenance

• Eight managed 5-15R outlets with pure sine wave output and two load banks enable outlet-level monitoring and load shedding strategies

  • Overview
  • Specifications
  • FAQ
  • User Guides
  • Reviews

The Eaton 5PX1000RTNG2 delivers enterprise-grade power protection in a compact 2U form factor designed for distributed IT deployments. This line-interactive UPS combines unity power factor technology with 98% efficiency to maximize power delivery while minimizing energy costs and cooling requirements.

Built for environments where remote management and uptime are critical, the 5PX G2 includes a pre-installed gigabit network card that meets rigorous cybersecurity standards. The intuitive graphical LCD display and configuration wizard simplify deployment, while hot-swappable batteries and support for up to four extended battery modules provide flexible runtime options without service interruption.

Best For

Enterprise IT infrastructure requiring reliable power protection with advanced remote management capabilities:

- Edge Computing Deployments: Branch office servers, network switches, and PoE equipment needing rack-mount power protection with centralized monitoring

- Small Business IT Closets: Networking equipment, VoIP systems, and storage devices in space-constrained environments requiring 2U rack density

- Healthcare Facilities: Medical workstations, pharmacy systems, and patient data equipment requiring pure sine wave output and battery backup

- Retail Point-of-Sale Systems: Payment terminals, inventory management servers, and wireless access points needing surge protection and battery runtime

- Financial Services Networks: Trading workstations, transaction processing servers, and network infrastructure requiring high-efficiency power conditioning

Key Features

- Unity power factor (1.0) design provides full 1000W output at 1000VA rating, eliminating traditional derating for modern power factor corrected loads

- Automatic Voltage Regulation (AVR) corrects voltage fluctuations without switching to battery, extending battery life and runtime availability

- Two independently controllable load banks enable non-critical load shedding during extended outages to prioritize runtime for essential equipment

- Graphical LCD display shows real-time power metrics, runtime estimates, and configuration options with startup wizard for simplified deployment

- Brightlayer Data Centers software suite provides centralized monitoring, configuration, and firmware management across distributed UPS installations

- Expandable runtime supports up to four 5PXEBM48RTG2 extended battery modules for applications requiring extended outage protection

- Dual form factor supports 4-post 19-inch rack mounting or tower installation with included support stands for flexible deployment options

- USB and RS-232 serial interfaces included for local server communication and graceful shutdown integration with major operating systems

Quick Specs

Model Number 5PX1000RTNG2
Power Capacity 1000 VA / 1000 W
Topology Line-Interactive
Input Voltage 120 VAC (50/60 Hz)
Input Connection NEMA 5-15P, 10 ft cord
Output Voltage 100/110/120/125 VAC
Output Waveform Pure Sine Wave
Output Receptacles (8) NEMA 5-15R, 2 load banks
Runtime (Full Load) 6 minutes at 1000W
Runtime (Half Load) 17 minutes at 500W
Battery Type Valve Regulated Lead Acid (VRLA)
Battery Replacement User replaceable, hot-swappable
Extended Battery Support Up to 4 EBMs (5PXEBM48RTG2)
Efficiency (Max Load) 98%
Network Management NETWORK-M2 Gigabit card (pre-installed)
Communications USB (HID), DB9 Serial, Network Card
User Interface Graphical LCD display
Form Factor 2U Rack/Tower
Dimensions (H×W×D) 3.4" × 17.2" × 17.6" (86 × 437 × 447 mm)
Weight 44.5 lb (20.2 kg)
Operating Temperature 32° to 104°F (0° to 40°C)
Relative Humidity 20-90% non-condensing

What's Included

- Eaton 5PX1000RTNG2 UPS with pre-installed NETWORK-M2 gigabit network card

- Rack-mounting hardware for 4-post installation

- Tower support stands

- USB cable

- RS-232 serial cable

- Quick Start Guide

- Safety Guide

Product Details
Color Black
Power Source AC-powered
What type of IT equipment and environments is the 5PX1000RTNG2 best suited for?
This UPS is designed for distributed IT deployments including edge computing, branch offices, small business server rooms, and department-level infrastructure. The 2U rack form factor and 1000W capacity suit networking equipment, small servers, storage devices, VoIP systems, and PoE switches. The included network card and 98% efficiency make it ideal for remotely managed installations where operating costs and centralized monitoring matter.
How does the 5PX1000RTNG2 compare to other models in the Eaton 5PX G2 series?
The 5PX1000RTNG2 is the entry-level 2U rack model with network management included. It provides 1000VA/1000W capacity suitable for smaller equipment loads. Higher-capacity models (1500VA and above) offer more outlets and runtime but occupy the same 2U space. The "N" designation indicates the pre-installed network card, eliminating the need for separate purchase and installation compared to the base 5PX1000RTG2 model.
Is the 1000VA capacity and price point appropriate for typical small office network equipment?
The 1000W real power capacity handles typical small office loads including one server, multiple network switches, wireless access points, and VoIP equipment. The unity power factor design delivers more usable power than older UPS models rated at 1000VA but limited to 700-800W. The included network card and 98% efficiency provide value for managed environments, while extended battery support allows runtime expansion without replacing the base unit.
What systems and equipment can connect to the 5PX1000RTNG2 for power protection?
The eight NEMA 5-15R outlets accept standard North American plugs and deliver pure sine wave output compatible with all IT equipment including servers, switches, routers, storage systems, and workstations. The USB and serial interfaces support graceful shutdown integration with Windows, Linux, macOS, and major virtualization platforms. The pre-installed NETWORK-M2 card works with Eaton Brightlayer software for centralized management across mixed vendor environments.
What is the actual runtime on battery power for different equipment loads?
The internal battery provides 6 minutes runtime at full 1000W load and 17 minutes at half load (500W). Runtime extends significantly at lighter loads typical of network equipment. You can add up to four 5PXEBM48RTG2 extended battery modules to multiply runtime without UPS replacement. The two independently controlled load banks let you shed non-critical loads during extended outages to preserve runtime for essential equipment.
Can the batteries be replaced without shutting down connected equipment?
The batteries are user-replaceable and hot-swappable, allowing replacement while the UPS continues powering connected equipment from AC input. The advanced battery management system provides advance warning when replacement is needed. This eliminates scheduled downtime for battery maintenance in 24/7 environments.
What remote management capabilities does the included network card provide?
The pre-installed NETWORK-M2 gigabit network card enables web browser access for configuration, email alerts for power events, SNMP monitoring integration, and remote firmware updates. It supports secure protocols and meets UL 2900-1 and IEC 62443-4-2 cybersecurity standards. The card works with Eaton Brightlayer Data Centers software for centralized management of multiple distributed UPS units from a single console.
How much rack depth is required for installation in a standard server cabinet?
The UPS requires a minimum rack depth of 21 inches when using the included 4-post mounting hardware. The unit itself measures 17.6 inches deep, with additional clearance needed for rear cable connections and airflow. The mounting rails adjust to fit most standard 19-inch equipment racks. Tower installation uses the included support stands and requires no rack space.
$1,200.00
Regular price
$1,092.00
Sale price
$1,092.00
$1,200.00
Regular price
$1,092.00
Sale price
$1,092.00
In stock

Order by 3 PM EST for Same-day Fulfillment

Get approved for Net 30 Terms today —> Apply Now!
Bulk Pricing
10+ Quote request for exact pricing

YOU MAY ALSO LIKE