Skip to product information
1 of 1

Honeywell 760008A Full Facepiece Respirator with Dual Cartridge Ports for Industrial Air Protection

Delivery Time: 0-3 days
Brand Honeywell
Model Number 760008A
EpicRise Warranty First Year
Product Highlights

• Medical-grade silicone facepiece with wide sealing surface fits multiple face shapes for secure, comfortable all-day wear

• 200° field of vision with polycarbonate lens meets ANSI Z87.1 high-impact requirements for clear sight lines in all directions

• Five-point harness and dual-flange seal design ensures proper face-to-facepiece contact for reliable respiratory protection

• Built-in speech diaphragm improves voice clarity and workplace communication without removing the respirator

• Converts to PAPR or continuous-flow supplied-air systems for flexible protection across multiple work environments

• Nose cup reduces dead space and directs exhaled air away from lens to minimize fogging during extended use

  • Overview
  • Specifications
  • FAQ
  • User Guides
  • Reviews

The Honeywell 760008A 7600 Series Full Facepiece Respirator delivers versatile respiratory protection for industrial environments where workers face exposure to gases, vapors, and airborne particulates. This medium/large size respirator combines medical-grade silicone construction with dual N-series cartridge ports, offering reliable protection that adapts to multiple hazard scenarios. The wide sealing surface and five-point harness system ensure secure fit across diverse face shapes, while the integrated speech diaphragm maintains clear communication in noisy work settings.

Built for demanding industrial applications, this NIOSH-approved respirator features polycarbonate lenses that provide over 200° field of vision with superior optical clarity. The hard-coated lens surface resists scratches and meets ANSI Z87.1 impact standards, protecting both eyes and respiratory system simultaneously. When workplace requirements change, the 760008A converts to powered air-purifying or supplied-air configurations without replacing the facepiece, reducing total cost of ownership for safety programs.

Best For

The 760008A serves industrial operations requiring reliable full-face respiratory protection against multiple airborne hazards:

- Chemical processing facilities where workers handle volatile organic compounds, acids, or caustic materials requiring eye and respiratory protection

- Manufacturing operations with exposure to metal fumes, spray painting, or chemical vapor processes demanding extended-wear comfort

- Oil and gas industry maintenance and turnaround projects requiring adaptable protection from H2S, hydrocarbons, and particulate exposure

- Steel and metalworking environments where workers face grinding dust, welding fumes, and chemical treatments requiring convertible protection options

- Maintenance and remediation work in confined spaces or hazardous material sites requiring clear vision and reliable face seal

Key Features

- Dual-flange medical-grade silicone facepiece conforms to facial features without hardening over time, maintaining seal integrity through temperature extremes

- Five-point textile harness with quick-adjust hardware distributes pressure evenly and allows proper positioning without readjustment between uses

- Threaded dual cartridge connection system accepts North N-series cartridges, filters, and combination units including P100-rated options for customized protection configurations

- Polycarbonate lens with scratch-resistant coating provides unobstructed downward and peripheral vision for safe navigation in industrial environments

- Nose cup design channels exhaled air away from lens surface while reducing dead air space for improved wearer comfort during physical work

- Neck strap allows workers to hang respirator when not in use without removing harness, maintaining fit settings between protection cycles

- Chin cup guides proper facepiece positioning and enhances lower face seal for workers with various facial structures

- Compatible with welding adapter accessories for arc welding applications requiring combined respiratory and face protection

Quick Specs

Model Number 760008A
Size Medium/Large
Facepiece Material Medical-grade silicone
Lens Material Hard-coated polycarbonate
Cartridge Connection Dual threaded ports for N-series cartridges (P100-compatible)
Harness Type Five-point adjustable textile
Field of Vision Over 200° horizontal and vertical
Speech Diaphragm Standard (integrated)
Latex Content Latex-free construction
Convertible Design Compatible with PA 700 PAPR and CF2000 SAR systems
Weight 2.3 lbs (facepiece only)
Dimensions 2.3" W x 1" H x 1" L

What's Included

- 760008A full facepiece respirator with integrated speech diaphragm and five-point harness

- Neck strap for hands-free carrying

Note: Cartridges and filters sold separately - select appropriate N-series cartridges based on specific workplace hazards

What types of industrial environments is the 760008A respirator designed for?
The 760008A handles chemical processing, manufacturing with spray operations, oil and gas maintenance, metalworking facilities, and confined space work. It protects against gases, vapors, particulates, and provides simultaneous eye protection in environments requiring NIOSH-approved full-face respiratory protection. The silicone construction withstands temperature extremes and chemical exposure common in heavy industry.
How does the medium/large 760008A compare to the small size 760008AS in the same series?
Both models share identical silicone construction, five-point harness, 200° vision, and dual cartridge design. The 760008A accommodates larger facial dimensions with wider sealing surface and longer face length. Proper fit testing determines which size provides adequate seal - medium/large fits most industrial workforce demographics while small size serves workers with narrower facial structures.
Is the 760008A worth the investment compared to half-mask respirators for industrial safety programs?
The 760008A provides simultaneous eye and respiratory protection in single-device format, eliminating need for separate safety glasses. Full-face design delivers higher assigned protection factors than half-masks and converts to PAPR or supplied-air systems without replacing the facepiece. The medical-grade silicone maintains seal integrity longer than elastomer alternatives, reducing replacement frequency in multi-year safety programs.
What cartridge systems and respirator accessories work with the 760008A?
The 760008A accepts all North N-series threaded cartridges, filters, and combination cartridge-filter units through dual-port connections. It converts to Honeywell PA 700 series powered air-purifying units and CF2000 continuous-flow supplied-air systems using appropriate adapters. Welding adapter accessory (model 8419) and auto-darkening filters enable arc welding applications requiring combined respiratory and face protection.
What maintenance intervals does the silicone facepiece require in daily industrial use?
Clean the silicone facepiece after each use with mild soap and warm water, inspecting seal surfaces for damage or contamination. Replace the facepiece when silicone shows permanent deformation, tears, or loss of flexibility. The harness, lens, speech diaphragm, and nose cup are individually replaceable components - inspect before each use per OSHA respiratory protection program requirements.
Can workers wearing prescription glasses use the 760008A effectively?
The 760008A accommodates prescription lens inserts designed specifically for 7600 series facepieces, maintaining proper seal and optical alignment. Standard eyeglasses interfere with face seal and compromise respiratory protection. Honeywell offers prescription lens kits that mount inside the facepiece without affecting seal integrity or field of vision.
How does the speech diaphragm affect communication in high-noise industrial settings?
The integrated speech diaphragm transmits voice frequencies more effectively than speaking through sealed facepiece material alone. It improves intelligibility in moderate noise environments but does not replace two-way radio systems in high-decibel facilities. The diaphragm requires no maintenance beyond standard facepiece cleaning and does not compromise respiratory seal when properly installed.
What fit testing protocols does the 760008A require before workplace use?
OSHA requires quantitative or qualitative fit testing before initial use and annually thereafter, following 29 CFR 1910.134 protocols. The 760008A is available in two sizes (small and medium/large) - fit testing determines which size achieves adequate seal for each worker's facial dimensions. Users must perform positive and negative pressure user seal checks before each use per manufacturer instructions.
Does the 760008A package include cartridges or filters for immediate deployment?
The 760008A ships as facepiece assembly only without cartridges or filters. Purchasers must separately order appropriate North N-series cartridges based on specific workplace respiratory hazards identified through exposure assessment. This approach allows organizations to stock multiple cartridge types for the same facepiece platform across different work areas or tasks.
Regular price
$224.00
Sale price
$224.00
Regular price
$224.00
Sale price
$224.00
In stock

Order by 3 PM EST for Same-day Fulfillment

Get approved for Net 30 Terms today —> Apply Now!
Bulk Pricing
10+ Quote request for exact pricing

YOU MAY ALSO LIKE